Ventilation controllers Senseair

SenseAir is a modern, microprocessor-controlled detector of carbon dioxide (CO 2 ), temperature (T) and humidity (RH). They monitor the fundamental parameters of indoor air quality in buildings. Their primary use is control of ventilation and air conditioning in public/commercial/industrial buildings in accordance with client needs. They enable significant savings in ventilation operating costs without sacrificing air quality.

Areas of ​​application

  • public buildings,
  • mushroom farms,
  • greenhouses (amount of crop yield),
  • fruit and vegetable storage (long-term storage),
  • breweries, gas storage facilities and other facilities where CO 2 is a technological medium or by-product (OHS).

Features

  • highly selective measurement based on NDIR absorption,
  • no disturbance from other gases,
  • total resistance to periodic exceeding of the measuring range (up to 100% by volume),
  • long service intervals due to internal auto-calibration procedure;
  • all detectors are calibrated in GAZEX’s own Calibration Laboratory operating in accordance with PN-EN ISO / IEC 17025 (PCA accreditation No. AP150).

Offered models

Model Sensor Substance/property Standard alarm thresholds or measuring range Supply voltage Net price C.g.
Infra-red Carbon dioxide (CO2)
Temperature (T)
0 ÷ 2000
0 ÷ 50
ppm
°C
24VDC PLN1,199.00 N
Infra-red Carbon dioxide (CO2)
Temperature (T)
0 ÷ 2000
0 ÷ 50
ppm
°C
24VDC PLN1,299.00 N
Infra-red Carbon dioxide (CO2)
Temperature (T)
0 ÷ 2000
0 ÷ 50
ppm
°C
24VDC N
Infra-red Carbon dioxide (CO2)
Temperature (T)
0 ÷ 2000
0 ÷ 50
ppm
°C
24VDC PLN1,499.00 N
Infra-red Carbon dioxide (CO2)
0 ÷ 2000
ppm
24VDC PLN859.00 N
Infra-red Carbon dioxide (CO2)
0 ÷ 2000
ppm
24VDC PLN959.00 N
Infra-red Carbon dioxide (CO2)
0 ÷ 2000
ppm
24VDC N
Infra-red Carbon dioxide (CO2)
0 ÷ 2000
ppm
24VDC PLN1,159.00 N
Model Sensor Substance/property Standard alarm thresholds or measuring range Supply voltage Contact control outputs Voltage control outputs 12VDC Two-state outputs (threshold) Control output "Fault" Output controlling the shut-off valve Output in 4-20mA standard Output in 0-10V standard Output in 2-10V standard Output in RS-485 standard Visual signalling, built-in Acoustic signaling, built-in Internal battery Dimensions Net price C.g.
Infra-red Carbon dioxide (CO2)
Temperature (T)
0 ÷ 2000
0 ÷ 50
ppm
°C
24VDC 82 x 120 x 30 mm PLN1,199.00 N
Infra-red Carbon dioxide (CO2)
Temperature (T)
0 ÷ 2000
0 ÷ 50
ppm
°C
24VDC 82 x 120 x 30 mm PLN1,299.00 N
Infra-red Carbon dioxide (CO2)
Temperature (T)
0 ÷ 2000
0 ÷ 50
ppm
°C
24VDC 84 x 142 x 46 mm N
Infra-red Carbon dioxide (CO2)
Temperature (T)
0 ÷ 2000
0 ÷ 50
ppm
°C
24VDC 84 x 142 x 46 mm PLN1,499.00 N
Infra-red Carbon dioxide (CO2)
0 ÷ 2000
ppm
24VDC 80 x 100 x 28 mm PLN859.00 N
Infra-red Carbon dioxide (CO2)
0 ÷ 2000
ppm
24VDC 80 x 100 x 28 mm PLN959.00 N
Infra-red Carbon dioxide (CO2)
0 ÷ 2000
ppm
24VDC 84 x 142 x 46 mm N
Infra-red Carbon dioxide (CO2)
0 ÷ 2000
ppm
24VDC 84 x 142 x 46 mm PLN1,159.00 N