WG-22.NGA24s
Product model withdrawn from sale
Device group: Ventilation controllersDevice type: WG.NG Description of device type
WG-22.NG microprocessor-controlled detector is used for continuous monitoring of carbon monoxide (CO) levels in air. The monitoring is performed in premises where the gas is likely to occur, through periodic measuring of CO levels. When the preset threshold levels are exceeded, visual and acoustic alarms of the detector are engaged and its control outputs are activated.
Scope of application
- Closed garages and underground parking lots – ventilation control
- Boiler rooms with furnaces fuelled by solid or liquid fuels
- Gas-fuelled boiler rooms
- Production buildings where CO is likely to occur (technological processes)
- Permanently manned premises adjacent to boiler rooms
- Premises with equipment fuelled by coke-oven gas
Features
- Measurement of carbon monoxide at extremely low levels;
- Easily exchangeable sensor unit;
- Built-in microprocessor controlling all functions of the detector = reliability, work stability, temperature compensation, fully automatic unit;
- Gas detector + power supply + siren + control unit – all in one solid case, IP43;
- Two (or three) independent alarm thresholds calibrated to industry standards or tailored to customer’s requirements;
- FAULT relay output triggered by detector failure, blown fuse or power supply failure;
- 12VDC alarm output to control external sirens or lamps;
- 12VDC power supply – model WG-22A; option: 24VAC/DC;
- Optional: built-in battery back-up (up to 6h) – model WG-22B;
- All detectors are calibrated in our own GAZEX Calibration Laboratory operating in accordance with PN-EN ISO/IEC 17025 (PCA accreditation No AP150).
Block diagram
Device model: WG-22.NGA24s
Technical parameters
- Contact control outputs
- 2
- Voltage control outputs 12VDC
- 1
- Control output "Fault"
- Visual signalling, built-in
- Acoustic signaling, built-in
- Supply voltage
- 24VDC
- Dimensions
- 165 x 190 x 96 mm
Gas sensor module | Sensor | Substance/property | Standard alarm thresholds or measuring range | |
---|---|---|---|---|
MS-22.EG-EN | Semiconductor |
Carbon monoxide (CO) |
20/100/(300) |
ppm |
Documentation
Series | Technical data | Device information sheet | User Manual | Declaration of conformity |
---|---|---|---|---|
W1 | — | — | — | — |
Archived series | ||||
U5 | — | — | — | — |
U4 | Download file | — | — | — |
Suggested products
TP-4.s
Internal LED warning boards to visually present the alarm status appearing at the control outputs